POWER DISTRIBUTION & LOW VOLTS DISCONNECT PANELS |
| |
- 1U or 2U, 19" or 23" rack-mount
- Single Bus or Dual Bus (A/B)
- Operating Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
- Fuse Panels 80-150A per Bus
- Breaker Panels 150-300A per Bus
- Low Voltage Disconnects 70-600A per Bus
|
| |
Call us NOW for immediate delivery! |
|
| |
1U High Rack-mount Fuse Panels |
| |
|
|
|
| |
|
|
|
| |
|
|
|
- GMT Fuses
- All Connections Made at the Front
- Single Bus, 4 or 6 Fuses
- Dual Bus (A/B), 4 or 6 Fuses per Bus
- Bus Capacity: 80A per Bus
- Fuses rated from 1/2A to 20A
- Operating Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
|
- GMT Fuses
- Single Bus with 10 Fuses
- Dual Bus (A/B) with 10 Fuses per Bus
- Bus Capacity: 80A per Bus
- Fuses rated from 1/2A to 12A
- Operating Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
|
-------------------------------------------------------------------- |
-------------------------------------------------------------------- |
|
|
| |
|
|
|
|
|
| |
|
|
|
- Type KTK Fuses
- Single Bus with 5 Fuses
- Dual Bus (A/B) with 5 Fuses per Bus
- Bus Capacity: 150A per Bus
- Fuses rated from 100mA to 30A
- Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
|
- Type 70 Fuses
- Single Bus with 6 Fuses
- Dual Bus (A/B) with 6 Fuses per Bus
- Bus Capacity: 60A per Bus
- Fuses rated from 1/2A to 10A
- Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
|
| |
|
|
|
Rack-mount Breaker Panels |
| |
|
|
|
| |
|
|
|
| |
|
- Magnetic Circuit Breakers
- Single Bus with 6 Breakers
- Dual Bus (A/B) with 6 Breakers per Bus
- Bus Capacity: 150A per Bus
- Breakers rated from 1A to 50A
- Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
|
- Magnetic Circuit Breakers
- Single Bus with 4 Breakers
- Dual Bus (A/B) with 4 Breakers per Bus
- Bus Capacity: 50A per Bus
- Breakers rated from 5A to 50A
- Voltage: 120 or 230VAC
- NEMA or Screw Terminal Load Connections
|
---------------------------------------------------------------------------------------------------------------------------------------------------- |
| |
| |
|
|
| |
|
|
| |
|
- Magnetic Circuit Breakers
- Dual Bus (A/B) with 9 Breakers per Bus
- Bus Capacity: 300A per Bus
- Breakers rated from 1A to 100A
- Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
|
|
|
| |
|
Rack-mount Combination Panels & Low Voltage Disconects |
| |
|
| |
|
|
| |
|
| |
|
|
| |
|
- Dual Section (A/B)
- Current Capacity per Section: 60A to 150A
- Operating Voltage: 12, 24 or 48VDC
- Positive or Negative Ground
- A & B are Isolated Loads
- Combination of Fuses, Breakers, LVD
- GMT, KTK or Type 70 Fuses
- 1A to 50A Circuit Breakers
- LVD has Battery Circuit Breaker
- LVD in Series with Battery or Load
|
-------------------------------------------------------------------- |
-------------------------------------------------------------------- |
|
|
|
|
| |
|
|
|
- Single or Dual (A/B) LVDs
- Current Capacity: 70A per Load
- Operating Voltage: 24 or 48VDC
- Positive or Negative Ground
- LVD in Series with Battery or Load
- Battery Circuit Breaker:100A
- LVD Bypass Switch, Optional
|
- Single or Dual (A/B) LVDs
- Current Capacity: 400A or 600A per Load
- Operating Voltage: 24 or 48VDC
- Positive or Negative Ground
- LVD in Series with Battery or Load
|
|
|
| |
|