Chat Online with UNIPOWER Corporation Representative
Commercial / Industrial / Medical Power SolutionsFor Information call:
North America: +1 (954) 346-2442 x1071
Europe: +44 (0)1903 768200
View Cart

MEDIMOD AJ-040UM-S Series - Medical Switchers

All products can be customized to meet specific requirements.
40 watts - 3.6” x 3.5”

Medical Switcher, 40W, AJ-040UM-S, Power Supply

PDF Datasheets

For Support call:
North America: 954-346-2442 x1071
Europe: +44(0) 1903 768 200

Stocked / Off-The-Shelf Models

Listed below are common configurations stocked by UNIPOWER for immediate delivery.
Single Output Models
Models V1 MIN CON AIR PEAK Buy
AJ-040UM-S1-STD 5V 0A 6.0A 5.0A 9.5A Call to Order
AJ-040UM-S2-STD 12V 0A 2.5A 3.3A 4.0A Call to Order
AJ-040UM-S4-STD 24V 0A 1.3A 1.7A 2.1A Call to Order
AJ-040UM-S5-STD 48V 0A 0.6A 0.8A 1A Call to Order
MIN = Minimum Load Required for specified regulation
CON = Maximum continuous output current with Convection Cooled Operation (Total power not to exceed 30 Watts continuous)
AIR = Maximum continuous output current with 15 CFM Airflow Operation (Total power not to exceed 40 Watts continuous)

Flexible Output Configuration Guidelines

with 90-264 VAC Input and -20-50°C Operation
SINGLE OUTPUT MODELS 3.3 to 48VDC (7,11) / OUTPUT CURRENT / AMPS
Output Current 1.5v~3.3V 5V 12V 15V 24V 48V
Minimum 0 0 0 0 0 0
Maximum (3) 6 6 2.5 2 1.3 0.6
Maximum (4) 8 8 3.3 3.6 1.7 0.8
Peak (4,5) 9.5 9.5 4 3.3 2.1 1
NOTES: (1) Full power out on V3-V4 with minimal V1 and V2 loading—Option. (2) 10% minimum load for stated regulation on multiple O/P units. (3) Convection cooling. (4) 30CFM forced air cooling. (5) 30 seconds maximum duration. (6) Most output combinations from 2 to 48+ Volts possible; up to maximum rated Current / Power...Consult EASYMOD Support. (7) Specify 0.1V increments. (8) Specific output voltage is current dependent. (9) Regulation may degrade under some output conditions. Consult EASYMOD Support. (10) Consult EASYMOD Support for Model #. (11) For outputs >48 Volts, consult EASYMOD Support. (12) Cover and custom sheet metal available.

Features and Options

Full Power @ Minimal 5 Volt Load
MTBF >200,000 Hours
2-48 VDC Outputs Available
Wide Operating Temp. Range
0.5% Pk-Pk Ripple Options
UL-CSA-TUV-“CE” Approval
3.6” x 2.5” x 1.2” High
-40ºC Start-Up-Option
DC Input Models Available

Warranty

Unipower 5 Year Warranty

Input Specifications

Input Voltage: 47-63 Hz; 90-264 VAC
Power Factor: Meets EN61000-3-2 Amendment 14
Inrush Current, Cold Start: 25A max
Input Current @ 115VAC: 0.5A P- P
Fusing: 3.15A @ 250 VAC On Board

Output Specifications

Continuous Output Power: 40 Watts
Holdup Time: 16 mSec
Line Regulation Over Input Range; V1-V4: ± 0.2%
Load Regulation @ 60% 4 0%
Full Load
- V1: ± 3%
- V2-V3: ± 5% max
Cross Regulation @ 60% 40%
Full Load
- V1: Change in V2-V4: ± 0.5%
- V2-V4: Change in V1 @75 25% F/L: ± 5% max
Overvoltage Protection V1: 125% Vout typ
Overshoot, All Outputs: 10% max
Power Limit: Set @120% typ
Response Time: 500 μSec
Ripple & Noise @ 20 Mhz Band Width
Full Load - All Outputs: 1% P-P max
Output Adjustment Range on V1: 5% min

General Specifications

Efficiency: 70% typ
Switching Frequency: 60KHz typ
Immunity: See datasheet
Operating Temperature Range: -20 to +70ºC
Minimum Start-up Temperature: -20ºC
Derating from 50-70ºC: 2.5%/ºC
Storage Temperature: -40 to +85ºC
Cooling: See Note 5
Relative Humidity
Non-Condensing: 5-95%
Altitude: 10,000 ft
EMI: FCC Class B & VDE Class B - CISPR 22; EN 55022 Class B; EN55024
Vibration from 10-55Hz: 1.0G Peak
MTBF per MIL 217: > 250,000 hours
Safety Agency Approvals: UL & cUL 60950 & 2601; EN 60950; IEC 601-1; CE